Location:Home > Products > Furnace front carbon silicon analyzer > Carbon silicon analyzer in front of the furnace
Description:The KD-TS furnace pre-furnace carbon silicon analyzer performs thermal analysis of white iron, gray cast iron and ductile iron. Determination of molten iron CEL, C, Si, TL, TS, etc
Product Category
Furnace front molten iron analyzer
Infrared carbon and sulfur analyzer
Furnace front carbon silicon analyzer
High frequency infrared carbon sulfur analyzer
Direct reading spectroscopic analyzer
Molten iron quality management instrument
Hardness tester, tensile tester
Quality management instrument for molten iron in front of the furnace
Related articles
Related ArticlesIntroduction
KD-TS furnace pre-furnace silicon carbon analyzer
Key features:
It adopts anti-electromagnetic interference, dust insulation and portable design, which is easy to operate. The improved evaluation method can automatically measure important metallurgical parameters, making up for the shortcomings of the "spectrum" that cannot accurately measure non-metallic elements (C, Si) and the time requirements of conventional analytical instruments that cannot meet the pre-furnace analysis.
Main parameters of KD-TS furnace pre-furnace carbon silicon analyzer:
1. Measurement function: thermal analysis of white iron, gray cast iron and ductile iron.
2. Measurement parameters: determination of molten iron CEL, C, Si, TL, TS, △T, △TM
Determine the tensile strength Rm and hardness HB
3. Temperature measurement range: 1250°C~1350°C
4. Measuring range: C: 2.1~4.2% Si: 0~5.0% CEL: 2.5~5.0%
5. Accuracy: ≤±1°C CEL±0.047% C±0.05% Si±0.1%
6. Display: 4-digit LED display word height 50mm resolution: 1 °C
7. Operation mode: 9 buttons to select the required parameters, in which "Auto" displays CEL, C, SI, adjust the si content by rotating the potentiometer, and adjust the C content through the potentiometer.
8. Output mode: serial signal RS232-TTY current loop signal output.
9. Working parameters: power supply AC 220V, 50Hz; The power is 30W, and the ambient temperature is 0~50°C
10. Temperature compensation range: 0~15°C
11. Matching sample cup type: K type
12. Display temperature unit: Fahrenheit or Celsius can be set
13. Measurement time: 240 seconds (generally 1 minute 45 seconds)
14. Measurement status display: "Ready" green light, "Measure" yellow light, "Complete" red light display on the instrument
15. Instrument protection standard: IP65 standard protection
16. EMC standard: implement EN50081-2 and EN50082-2 standards
Product consultation